Pulse lineResearch With Heart Logo

Atherosclerosis Risk in Communities (ARIC) Carotid MRI flow cytometry study of monocyte and platelet markers: intraindividual variability and reliability.

TitleAtherosclerosis Risk in Communities (ARIC) Carotid MRI flow cytometry study of monocyte and platelet markers: intraindividual variability and reliability.
Publication TypeJournal Article
Year of Publication2008
AuthorsCatellier DJ, Aleksic N, Folsom AR, Boerwinkle E
JournalClin Chem
Volume54
Issue8
Pagination1363-71
Date Published2008 Aug
ISSN1530-8561
KeywordsAged, Antigens, CD, Biomarkers, Black or African American, Blood Platelets, Carotid Artery Diseases, Cohort Studies, Female, Flow Cytometry, Humans, Male, Monocytes, Prospective Studies, Reproducibility of Results, White People
Abstract

BACKGROUND: Cellular markers help identify different components of a pathological process and may contribute to the diagnosis, prognostic assessment, and management of patients with suspected syndromes. Flow cytometry can be used to accurately assess markers of platelet and leukocyte activation and cellular aggregation in whole blood. To use cell markers as predictors of disease requires that they be measured reliably and show modest within-individual, day-to-day variation.

METHODS: We used whole blood flow cytometry to analyze monocyte and platelet markers in the Atherosclerosis Risk in Communities (ARIC) Carotid MRI study. We estimated laboratory variability using 20 split samples, process variation using replicate blood tubes taken from 112 subjects, and biologic plus process variation using replicate blood samples taken 4-8 weeks apart from 55 people.

RESULTS: For most analytes, the laboratory CV was 0.90). Reliability coefficients based on repeat-visit data indicated substantial to high repeatability (R > 0.60) for CD14, Toll-like receptor (TLR)-2, CD162, CD61, CD41, CD62P, CD154, and platelet-leukocyte aggregates. In contrast, TLR-4, CD45, myeloperoxidase (MPO), and cyclooxygenase (COX)-2 had slight to moderate repeat visit reliability.

CONCLUSIONS: The high repeatability results for selected platelet and monocyte markers indicate that they can be reliably measured in multicenter studies with delayed sample processing, provided that rigorous standardization of sample collection, shipping, and flow cytometry procedures is applied.

DOI10.1373/clinchem.2007.102202
Alternate JournalClin Chem
PubMed ID18515256
PubMed Central IDPMC2637799
Grant ListN01HC55020 / HL / NHLBI NIH HHS / United States
N01HC55018 / HL / NHLBI NIH HHS / United States
N01-HC-55022 / HC / NHLBI NIH HHS / United States
U01 HL075572 / HL / NHLBI NIH HHS / United States
N01-HC-55019 / HC / NHLBI NIH HHS / United States
N01-HC-55015 / HC / NHLBI NIH HHS / United States
N01HC55019 / HL / NHLBI NIH HHS / United States
N01-HC-55016 / HC / NHLBI NIH HHS / United States
5U01HL075572 / HL / NHLBI NIH HHS / United States
N01HC55022 / HL / NHLBI NIH HHS / United States
N01-HC-55021 / HC / NHLBI NIH HHS / United States
U01 HL075572-01 / HL / NHLBI NIH HHS / United States
N01HC55015 / HL / NHLBI NIH HHS / United States
N01-HC-55020 / HC / NHLBI NIH HHS / United States
N01HC55016 / HL / NHLBI NIH HHS / United States
N01-HC-55018 / HC / NHLBI NIH HHS / United States
N01HC55021 / HL / NHLBI NIH HHS / United States